Load Bank, AC Load Bank, Load Bank for Generator Test manufacturer / supplier in China, offering Portable Type 100kw Three Phase AC Load Bank for Genset, 500kVA Diesel Generator Powered by Perkins 2506c-E15tag2 Engine and Stamford Hci544D Alternator, 100kVA Sound Proof Type Diesel Genset Powered by Cummins Diesel Engine and Stamford Alternator and so on.

(/ )

Supplier Homepage Product Load Bank Others Load Bank Portable Type 100kw Three Phase AC Load Bank for Genset

Portable Type 100kw Three Phase AC Load Bank for Genset

FOB Price: US $8,000-10,000 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $8,000-10,000/ Piece
Get Latest Price
Port: Fuzhou, China
Production Capacity: 500PCS/Year
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: KPLB-100
  • Mass Scope of Workpiece: 13200 Kg
  • Maxcapacity: 2500kVA
  • Load Way: Electronic & Mechanical Load
  • Display: Digital
  • Weight: 350-13200kg
  • Oil Cylinder Position: Nothing
  • Trademark: KEYPOWER
  • Specification: 960x960x1400 mm
  • HS Code: 8514109000
  • Max Diameter of Workpiece: 20FT Container
  • Type: Inductive & Resistive ,PF=0.8-1.0
  • Accuracy Grade: 0.5
  • Loading Method: Dynamic Load
  • Control: Computer & Manual Control
  • Power Source: 110-480V
  • Name: Portable Type 100kw Three Phase AC Load Bank for G
  • Transport Package: Standard Exportation Package
  • Origin: China
Product Description

Portable Type 100kw Three phase AC Load Bank for Genset
Portable Type 100kw Three Phase AC Load Bank for Genset

Product Details >>

KEYPOWER GENERATOR TESTER SPECIFICATIONS
MeasurementRangeAccuracyResolutionOverload
Voltage (V)10.0~500.0V± (0.4% reading+0.1%range)0.1V600V
Current (A)0.030~5.000A ± (0.4% reading+0.1%range)0.001A6A
PowerAccording to volt range 
&  current range
Power factor =1.0<200W 0.1W 
± (0.4% reading+0.1% range)≥200W 1W
Power factor =0.5≥2kW 10W
± (0.8% reading+0.2% range) 
Power Factor0.20~1.00±0.020.001 
Frequency45~65Hz±0.2Hz0.01Hz 
Running Time99h59m±2min/hour1 minute 
Energy
 (kWh)
99999kWh Power factor= 1.00.001kwh 
± (0.4% reading+0.1% range)
Power factor=0.5
± (0.8% reading+0.2% range)
Harmonic Analysis 
(%)
2-50 times 
and total harmonic
   
Models You Can Choose
ModelTesting 
capacity
Type 
of
 load
DutyCooling 
system
PhaseRated 
Testing 
Voltage
Rated
 Frequency
Dimensions   
   (L*W*H)
 (mm)
Weight
 (kg)
KPLB-1000 - 100 kwResistive 
or 
Reactive, 
 PF = 
1.0 or 0.8
ContinuousIndustrial 
grade 
axial fan
Available
 at both 
single 
and 
three 
phase
110-480 
VAC
50/60 Hz960*960*1400320
KPLB-2000 - 200 kw1300*1200*1570500
KPLB-3000 - 300 kw1600*1200*1700900
KPLB-4000 - 400 kw1600*1400*17001000
KPLB-5000 - 500 kw2100*1560*17001200
KPLB-6000 - 600 kw2100*1560*17001300
KPLB-7000 - 700 kw2100*1560*18001400
KPLB-8000 - 800 kw2100*1660*19001600
KPLB-10000 - 1000 kw2200*1900*21502000
KPLB-20000 - 2000 kw20 ft container6000
KPLB-50000 - 5000 kw40HC container16000
 
Specifications
100-2000KW Load Bank for Generator Load Test:

1.Premium components

2.Durable and reliable

3.Easy to transport 
Load bank is a simulating load test equipment used for generators, UPS,
battery banks etc power systems load test.
 

1. Resistive type of load, PF = 1.0. Stainless steel sheathed elements manufactured from high grade magnesium oxide.
2Rated testing voltage: AC 3P4W, 110-480V 50/60 Hz. 
3. Cooling mode: Forced air-cooled, fans mounted on the side of the load bank blow horizontally. Testing power or external utility power supply for fans. 
4. Working mode: Load step control
Total testing capacity ranges from 0kw to the max consisting of 10kw, 20kw, 50kw, 100kw load setting switches plus a 0-10kw fine-tuning knob. From 0kw to the max, any load combination is achievable. Load step resolution is 10kw. 
5. Load bank features world-famous components to ensure reliable performance and longer service life including:
    
Siemens switches, knobs and indicators. 
  
OMRON intermediate relays. 
PHOENIX terminal blocks. 
6.  Parameter measuring accuracy grade: 0.3 
7. Load control accuracy: &plusmn; 5%. 
8. Load bank protections: Over heating protection, cooling fans failure protection and over load protection with alarm. 
9. Control mode: Two control modes available:
A)Local manual control;
B)Optional: Manual control via a remote control panel (max control distance is 30m). 
10. Parameter display and measurement:
Control panel contains a LOVATO Multifunction Electricity Meter displaying voltage, current, load power, reactive power, apparent power, power factor, frequency etc.
(Optional: A professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing). " 
11. Operating environment:
Altitude: &le; 3000m above sea level. Ambient temp: -10~+50 ºC
Relative humidity: &le; 80% ventilated environment without explosive or corrosive dust. Not allowed to use in rainy outdoor environment.

Any question, please contact me directly. 
Portable Type 100kw Three Phase AC Load Bank for Genset
Portable Type 100kw Three Phase AC Load Bank for Genset


Portable Type 100kw Three Phase AC Load Bank for Genset
Portable Type 100kw Three Phase AC Load Bank for Genset

 

 

 

 

Send your message to this supplier
Avatar
Mr. Luis
*From:
To: Mr. Luis
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now