Fujian, China
Business Type:
Main Products:
Number of Employees:
Year of Establishment:
Management System Certification:
ISO9001:2008, ISO14001:2004
Average Lead Time:
Peak season lead time: one month
Off season lead time: one month
OEM/ODM Service
Sample Available
Spanish Speaker

Generator Testing Machine, Load Bank, Bank Load manufacturer / supplier in China, offering 300kw Load Bank, Generator Testing Machine, 110-480V, Load Bank Resistors, 116kw/145kVA Soundproof Electric Powerdiesel Generator with Cummins Engine, 25kVA\20kw Silent Diesel Generator with FAW Power Engine and so on.

Gold Member Since 2014
Audited Supplier
Supplier Homepage Products Load Bank Others Load Bank 300kw Load Bank, Generator Testing Machine, 110-480V, Load Bank Resistors

300kw Load Bank, Generator Testing Machine, 110-480V, Load Bank Resistors

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $13,200-14,400/ Piece
Port: Fuzhou, China
Production Capacity: 500PCS/Year
Payment Terms: L/C, T/T
Type: Load Bank
Installation Method: Fixed
Cooling Method: Air Cooled
Output Type: AC Three Phase
Conditions of Use: Land Use
Usage: Common Units

You Might Also Like


Basic Info

Model NO.: KPLB-300
Landuse Type of Unit: Ordinary
Power: Electronic
Power Factor: PF = 1.0 or 0.8
Frequency: 50Hz/60Hz
Color: Green/White/Blue/Red/Yellow
Load Step: 10kw
Rated Power: 0-300kw
Duty Cycle: Continuous
Power Range: 100kw to 2000kw
Application: Generator,UPS,Battery
Trademark: KEYPOWER
Transport Package: Standard Exportation Package
Origin: China
HS Code: 8514109000

Product Description

KEYPOWER 300kw Resistive Type Yellow color Generating Test with CE Certificate
300kw Load Bank, Generator Testing Machine, 110-480V, Load Bank Resistors
Product Details >>

Voltage (V)10.0~500.0V± (0.4% reading+0.1%range)0.1V600V
Current (A)0.030~5.000A ± (0.4% reading+0.1%range)0.001A6A
PowerAccording to volt range 
&  current range
Power factor =1.0<200W 0.1W 
± (0.4% reading+0.1% range)≥200W 1W
Power factor =0.5≥2kW 10W
± (0.8% reading+0.2% range) 
Power Factor0.20~1.00±0.020.001 
Running Time99h59m±2min/hour1 minute 
99999kWh Power factor= 1.00.001kwh 
± (0.4% reading+0.1% range)
Power factor=0.5
± (0.8% reading+0.2% range)
Harmonic Analysis 
2-50 times 
and total harmonic
Models You Can Choose
KPLB-1000 - 100 kwResistive 
 PF = 
1.0 or 0.8
axial fan
 at both 
50/60 Hz960*960*1400320
KPLB-2000 - 200 kw1300*1200*1570500
KPLB-3000 - 300 kw1600*1200*1700900
KPLB-4000 - 400 kw1600*1400*17001000
KPLB-5000 - 500 kw2100*1560*17001200
KPLB-6000 - 600 kw2100*1560*17001300
KPLB-7000 - 700 kw2100*1560*18001400
KPLB-8000 - 800 kw2100*1660*19001600
KPLB-10000 - 1000 kw2200*1900*21502000
KPLB-20000 - 2000 kw20 ft container6000
KPLB-50000 - 5000 kw40HC container16000

100-2000KW Load Bank for Generator Load Test:

1.Premium components

2.Durable and reliable

3.Easy to transport 
Load bank is a simulating load test equipment used for generators, UPS,
battery banks etc power systems load test.

1. Resistive type of load, PF = 1.0. Stainless steel sheathed elements manufactured from high grade magnesium oxide.
2Rated testing voltage: AC 3P4W, 110-480V 50/60 Hz. 
3. Cooling mode: Forced air-cooled, fans mounted on the side of the load bank blow horizontally. Testing power or external utility power supply for fans. 
4. Working mode: Load step control
Total testing capacity ranges from 0kw to the max consisting of 10kw, 20kw, 50kw, 100kw load setting switches plus a 0-10kw fine-tuning knob. From 0kw to the max, any load combination is achievable. Load step resolution is 10kw. 
5. Load bank features world-famous components to ensure reliable performance and longer service life including:
Siemens switches, knobs and indicators. 
OMRON intermediate relays. 
PHOENIX terminal blocks. 
6.  Parameter measuring accuracy grade: 0.3 
7. Load control accuracy: &plusmn; 5%. 
8. Load bank protections: Over heating protection, cooling fans failure protection and over load protection with alarm. 
9. Control mode: Two control modes available:
A)Local manual control;
B)Optional: Manual control via a remote control panel (max control distance is 30m). 
10. Parameter display and measurement:
Control panel contains a LOVATO Multifunction Electricity Meter displaying voltage, current, load power, reactive power, apparent power, power factor, frequency etc.
(Optional: A professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing). " 
11. Operating environment:
Altitude: &le; 3000m above sea level. Ambient temp: -10~+50 ºC
Relative humidity: &le; 80% ventilated environment without explosive or corrosive dust. Not allowed to use in rainy outdoor environment.

Any question, please contact me directly. 
300kw Load Bank, Generator Testing Machine, 110-480V, Load Bank Resistors
300kw Load Bank, Generator Testing Machine, 110-480V, Load Bank Resistors
300kw Load Bank, Generator Testing Machine, 110-480V, Load Bank Resistors
300kw Load Bank, Generator Testing Machine, 110-480V, Load Bank Resistors







Send your message to this supplier

avatar Miss Lily Wang

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now